High Rise Buildings Planning Permission Refusal Details - 2015

S.NO FILE NO SITE ADDRESS APPLICANT NAME DEVELOPMENT DETAILS REASONS FOR REFUSAL REFUSAL LETTER DATE REMARKS
1 C3/9268/2014 S.No.346/2A3pt, T.S.No.101, Block No.170 of Velachery Village, at Plot No.40 & 41, Door No.42/1 Velachery Main Road, Velachery, chennai. R.ARUNKUMAR Regularisation of existing Ground Floor + 3 Floors + 4th floor part Commercial Building. Site extent, Plot Frontage, Floor Space Index, Plot Coverage, Set back all around, T/W parking, Car parking, Lift, Generator Room, Transformer room, Meter room, Fire safety staircase, Provisions for differently abled persons, Drinking/Domestic Fire fighting Rainwater collection, Sullage water recycling , NOCs from DF and RS is not furnised. Structural Stability Certificate is not furnised, Architect has not signed in PPA and plan. Latest EC not furnished (The building) is completed and partly occupied by Textile showroom and Beauty clinic). Sump and OHT for fire fighting, Sullage water recycling and Rain water harvesting are not provided 17.04.2015
2 C3/12834/2014 T.S.No.4/1, Block No.39 of Virugambakkam Village, New NO.12, Old No.18, Vembuliamman Koil Street, virugambakkam, Chennai. M/S. MEENAKSHIAMMAL TRUST Additional construction of 3rd floor part for Block 1, School building, additional construction of Ground Floor part to the existing Block 1 (School building) Ground + 4 Floors, Block 2(Engineering College) Stilt + 5 floors, Block -3( Educational & Research University - 1) Groud + 3 Floor, Block -4(Educational & Research University - 2) Ground Floor + 3 Floors, Bank ATM Ground Floor, Study room. Clear set back at all floor levels of the building, Block 2 Engineering College Block -3 University 1 Block 4 University 4 , as per DR 25, Table (7), Sl.No.(C) the minimum Road width required for the site extent exceeding 2 hectres 18.00m where as the available road width varies from 9.38m to 12.95m only. Thus Road width is less by 5.05m to 8.62m. OSR area shown in the site plan is not demarcated with definite boundary in the site. OSR access from public road to be provided. Bye-cycle parking for 1280 Nos. to be shown in the plan. Structural Stability Sufficiency Certificate in the prescribed format (PP 1, PP2 & CC3) to be furnished. Lightning arrester and Aviation lamp to be shown in the plan and the same to be installed in the buildings. 2 Nos of lift are not provided in each block. Patta attested by the Revenue Authorities to be furnished. Plot boundary abutting road to be demarcted. Provisions for physically challanged are not provided. Noc from Police (Traffic) & DF & RS are not furnised. EIA clearance to be obtained . The form for Certificate for structural design sufficiency (PP1) & form for Supervision (PP2) are not furnished. 08.04.2015
3 C3/5173/2015 R.S.No.439/0 Block No.40 VOC Nagar Village Fort- Tondiarpet Taluk. THIRU.YOUNUS T.MILL WALA (M/S.DYANAMIC FOUNDATIONS) Regularisation of exising Ground Floor + 4 Floors + 5th floor part Commercial cum Residential Building. Site Extent, Plot Frontage, Abutting Road width, FSI, Plot Coverage, Set back all around, Two wheeler Parking , Car Parking, Lift, Generator Room, Transformer Room, Meter Room, Rain Water Harvesting not provided, NOCs from DF & RS and Traffic Police are not furnished. Sump for Domestic water, Rain water collection, Sullage water, Fire fighting are not provided and OHT for sullage water, Fire fighting are not provided, Lightening arrester is not shown in the plan, Waste Management structure is not provided, Structural Stability certificate is not furnished. 18.06.2015
4 C3/6396/2015 Door No.113/108, Audiappa Street, Sowcarpet, R.S.No.6910, Block No.59, VOC Nagar Village, Fort-Tondiarpet Taluk, Chennai. THIRU. MUNILAL & OTHERS. Regularisation of Exising Ground Floor + MF+4 Floors & 5th Floor Part Commercial cum Residential Building with 2 dwelling units. Site Extent, Plot Frontage, No of Floors Permissble, FSI, Plot Coverage, Set back all around, Parking for Two Wheeler, Car Parking, Lift , Generator Room, Meter Room, Transformer Room, Fire Safety Staircase, Lift, Structural Stability Certificate, Rain Water Harvesting, NOC from DF & RS and Traffic Police are not furnished, Provisions of physically challenged DR 28 (24) - Annexure XVI part II (B) and Annexure XXII is not required, Provisions for UG Sump for Drinking Water, Fire Fighting, Rain water collection, Sullage water recyling and OHT s for Fire fighting, Sullage are not made, Mezzanine Floor area exceeds 1/3rd area of the GF area, Lightening arrestor not provided, Qualifying road width of 12.0m is not uniformly available for a length of 500m, Plan does not reflect as on site condition. 18.06.2015
5 C3/6395/2015 Old No.9, New Door No.8, Audiappa Street, Sowcarpet, R.S.No.11070/0, Block No.88, VOC Nagar Village, Chennai. THIRU. S. SAMPATH & 3OTHERS. Existing Commercial Building (Shop) containing Ground+4Floors+5th Floor Part . Site Extent, Plot Frontage, FSI, Plot Coverage, Set back all around, Two Wheeler Parking, Car Parking, Lift, Gernerator Room, Transformer Room, Fire Safety Staircase, Meter Room, Rain Water Harvesting not provided, NOCs form DF & RS and Traffic Police are not furnished, Sump for Domestic water, Rain water collection, Sullage water, Fire fighting are not provided and OHT for sullage water, Fire fighting are not provided. 18.06.2015
6 C3/4412/2015 R.S.No.3229, Block No.29 of VOC Nagar Village Fort Tondiarpet Taluk, Chennai. S.SIVAPERUMAL & S. SIVAKUMAR Regularisation of existing Ground Floor + 5 Floors +6h Floor part Commercial cum Residential Building Site extent, Plot frontage, abutting Road width, FSI, Plot Coverage, No of Floors permissible, Height of the building above GL, Set back all around, Two wheeler Parking , Car Parking, Lift, Generator Room, Transformer Room, Meter Room, Rain Water Harvesting not provided,NOCs from DF & RS and Traffic Police are not furnished. 18.06.2015
7 C3/11256/2014 T.S.No.18Pt,Block No.16 Kalikundram Village S.S.HAJA MOHIDEEN PP Regularisation of the existing GF+2Floor+3Floor Part+4th Floor Part Commercial Building. Land Use, Plot Extent, Frontage, FSI, Plot Coverage, Height of the Building, FSB, SSB on both side, RSB, Car Parking, T/W Parking, Corridor Width, Generator Room, Transformer Room, Meter Room, Fire Safety Staircase, Structural Stability, Rain water Harvesting, Provision for differently able persons. Defects: Plans furnished do not reflect as on site condition, NOC from DF & RS, Architect has not signed in PPA and Plan, Lightening Arresstor is not provided, Exg G.L & Formed G.L are not shown in the section. 26/06/2015